Write your message
Volume 1, Issue 3 (Journal of Ergonomics 2014)                   Iran J Ergon 2014, 1(3): 27-35 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zare Derisi F, Rastegar L, Hosseini S, Daneshmandi H, Choobineh A, Mohammadbeigi A. Correlation of Astrand and ACSM Protocols in Estimating the Maximum Aerobic Capacity (Vo2-Max) . Iran J Ergon 2014; 1 (3) :27-35
URL: http://journal.iehfs.ir/article-1-49-en.html
1- Shiraz University of Medical Sciences
2- Shiraz University of Medical Sciences , daneshmand@sums.ac.ir
3- Qom University of Medical Sciences
Abstract:   (37852 Views)

Introduction: The maximum aerobic capacity (VO2-max) can be used to assess the cardio-respiratory condition and fit the physiological characteristics of workers to the work. This study was conducted to determine the correlation between the two methods of estimating the maximum aerobic capacity and its affecting factors among students of Shiraz University of Medical Sciences.

Materials and Methods: In this cross-sectional study, 104 students (54 males and 50 females) participated voluntarily (age ranged from 18 to 28 years). The subjects were assessed by step test according to Åstrand and ACSM protocols. The data collecting tool was a questionnaire including separate sections of demographic (age, sex, etc.), anthropometric (height, weight and BMI) and physiological (VO2-max) characteristics.

Results: The results revealed that the maximum aerobic capacity estimated from Åstrand and ACSM protocols were 3.21 (0.825) and 3.13 (0.707) l.min-1, respectively. Pearson correlation test showed high correlation between estimated maximum aerobic capacity via two protocols of Åstrand and ACSM (r=0.958). Meanwhile, there were significant associations among maximum aerobic capacity with weight, height, BMI and the number of hours of exercise per week.

Conclusion: The two methods for estimating the maximum aerobic capacity (Åstrand and ACSM) were highly correlated. Variables such as weight, height, BMI, and number of hours of exercise per week can be named as effective factors on VO2-m Normal 0 false false false EN-US X-NONE AR-SA
Full-Text [PDF 1160 kb]   (21418 Downloads)    
Type of Study: Research | Subject: Other Cases
Received: 2013/12/29 | Accepted: 2014/03/12 | ePublished: 2014/03/13

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Iranian Journal of Ergonomics

Designed & Developed by : Yektaweb |